Technical
- Input Voltage
- 380-480V
- Input Frequency
- 50 or 60 Hz
- Phase Rotation
- Any
- Input Protection
- Over/undervoltage | Loss of phase | Overcurrent | Short circuit
- Inrush Current
- No greater than 100% of full load current
- Output Voltage
- 115/200V
- Output Overload
- 100% continuous
- Crest Factor
- 1.414 +/- 3%
- Frequency Regulation
- 400 Hz
- Frequency Transients
- None
- Phase Angle Regulation
- +/- 1 degree (balanced loads) | +/- 2 degree (unbalanced loads)
- Harmonic Distortion
- 2.0% maximum
- Output Protection
- Overload | Short circuit | Over/undervoltage | Safety disconnect
- Automatic Line Drop Compensation
- 15%
- Acoustical Noise
- 65 dBA maximum at 5 ft
- Temperature Range
- -40°F - 131°F
- Relative Humidity
- 10 - 95%
- Ingress of Water
- Type 3RX, IP55
- Energy Efficiency
- 94% typical (full load) | 92% typical (half load)
- Energy Efficiency Ratio
- 20 typical
Details
- 3 Phase
- IP55
- Indoor/Outdoor use
- = 5% input current distortion
- Automatic input line monitoring
- Advanced Integrated Display (AID) Console
- 8,000 event log / diagnostics
- TCP/IP/Ethernet interface (Modbus)
- Emergency power "OFF" switch
- 18" hazard area clearance
- I/O Voltage, Current & Frequency Monitoring
- Elapsed time meter
- Sleep mode
- Front panel summary fault indicators
- Input & output cable racks
- Input high voltage transient protection